PL sērija
PL 40/63
Fast - SPOT - welding unit; spot fitting with foot pedal and front-mounted electrode support, closed cycle cooling system.
| Type name | PL 40 |
PL 63 |
| Power output at 50 % DR | 40 kVA | 63 kVA |
|---|---|---|
| Secondary short circuit current | 26,2 kA | 31,5 kA |
| Throat depth, freely selectable | 250 - 550 mm | 250 - 550 mm |
| Throat gap | 150 or 310 mm | 150 or 310 mm |
| Elektrodenkraft | 100 - 600 daN | 100 - 600 daN |
| Electrode force | max. 65 mm lift | max. 65 mm lift |
Technical properties
- Add-on control cabinet to accommodate the welding controller mounted on the right side of the machine Ready wired
- Closable viewing window
- MPS 10 control rack
- 5-time synchronous welding controller with 8 welding programs for operation with a thyristor power stage
- Digital current and time setting
- Slope control and impulse functions
- Power supply compensation
- Automatic mains frequency recognition 50/60 Hz
- Parameter entry via keypad on the control panel
- Status display via LEDs
- international operating symbols
- Stepping and locking contact
- Main switch in accordance with VDE 0113
- Corresponds to the standards VDE 0545-1, EN 60204-1, EN 50 240, EN 292 Parts 1+2, EN 1050
- CE mark
PL 80/100
Fast - SPOT - welding unit; spot fitting with foot switch and front-mounted electrode support, closed cycle cooling system.
| Type name | PL 80 |
PL 100 |
| Power output at 50 % DR | 80 kVA | 100 kVA |
|---|---|---|
| Secondary short circuit current | 35 kA | 41,5 kA |
| Throat depth, freely selectable | 350 - 650 mm | 350 - 360 mm |
| Throat gap | 160 or 360 mm | 150 or 310 mm |
| Electrode force | 100 - 600 daN | 100 - 600 daN |
| EH cylinder | max. 90 mm lift | max. 90 mm lift |
Technical properties
Add-on control cabinet to accommodate the welding controller mounted on the right side of the machine Ready wired
Closable viewing window
MPS 10 control rack
5-time synchronous welding controller with 8 welding programs for operation with a thyristor power stage
Digital current and time setting
Slope control and impulse functions
Power supply compensation
Automatic mains frequency recognition 50/60 Hz
Parameter entry via keypad on the control panel
Status display via LEDs
International operating symbols
Stepping and locking contact
Main switch in accordance with VDE 0113
Corresponds to the standards VDE 0545-1, EN 60204-1, EN 50 240, EN 292 Parts 1+2, EN 1050
CE mark