PL sērija

 

PL 40/63

Fast - SPOT - welding unit; spot fitting with foot pedal and front-mounted electrode support, closed cycle cooling system.

 

Technical data
Type name PL 40
PL 63
Power output at 50 % DR 40 kVA 63 kVA
Secondary short circuit current 26,2 kA 31,5 kA
Throat depth, freely selectable 250 - 550 mm 250 - 550 mm
Throat gap 150 or 310 mm 150 or 310 mm
Elektrodenkraft 100 - 600 daN 100 - 600 daN
Electrode force max. 65 mm lift max. 65 mm lift

Technical properties

  • Add-on control cabinet to accommodate the welding controller mounted on the right side of the machine Ready wired
  • Closable viewing window
  • MPS 10 control rack
  • 5-time synchronous welding controller with 8 welding programs for operation with a thyristor power stage
  • Digital current and time setting
  • Slope control and impulse functions
  • Power supply compensation
  • Automatic mains frequency recognition 50/60 Hz
  • Parameter entry via keypad on the control panel
  • Status display via LEDs
  • international operating symbols
  • Stepping and locking contact
  • Main switch in accordance with VDE 0113
  • Corresponds to the standards VDE 0545-1, EN 60204-1, EN 50 240, EN 292 Parts 1+2, EN 1050
  • CE mark



PL 80/100

Fast - SPOT - welding unit; spot fitting with foot switch and front-mounted electrode support, closed cycle cooling system.

 

Technical data
Type name PL 80
PL 100
Power output at 50 % DR 80 kVA 100 kVA
Secondary short circuit current 35 kA 41,5 kA
Throat depth, freely selectable 350 - 650 mm 350 - 360 mm
Throat gap 160 or 360 mm 150 or 310 mm
Electrode force 100 - 600 daN 100 - 600 daN
EH cylinder max. 90 mm lift max. 90 mm lift

Technical properties

Add-on control cabinet to accommodate the welding controller mounted on the right side of the machine Ready wired
Closable viewing window
MPS 10 control rack
5-time synchronous welding controller with 8 welding programs for operation with a thyristor power stage
Digital current and time setting
Slope control and impulse functions
Power supply compensation
Automatic mains frequency recognition 50/60 Hz
Parameter entry via keypad on the control panel
Status display via LEDs
International operating symbols
Stepping and locking contact
Main switch in accordance with VDE 0113
Corresponds to the standards VDE 0545-1, EN 60204-1, EN 50 240, EN 292 Parts 1+2, EN 1050
CE mark